Type: Ozone Water Purifier
Usage: Environmental Protection, Chemical Industry
Motive Force: Pressure
Style: Vertical
Performance: Efficient Filtration
Certification: CE, GS, RoHS
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Shanghai, China
Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Fast Delivery
The supplier can deliver the goods within 15 days
Full Customization
The supplier provides full customization services
to see all verified strength labels (15)

Basic Info.

Model NO.
JYBF
Filtration Precision
20----2,000um
Standard Designed Pressure
0.7MPa/1.0MPa
Working Temperature
5. 0-95ºC
Flow Range
17--10,560m3/H
Cleaning Pressure Difference
0.05MPa-0.07MPa
Control System
Siemens Controller
Gear Motor
180W/370W
Connection
Flanged
Inlet
2 Inch---24 Inch
Outlet
DN50----DN1000
Material of Cartridge
304ss/316lss
Material of Housing
304ss/316lss/Carbon Steel
Material of Sealing
Butadiene/ EPDM
Actuator of Valve
Pneumatic or Electric, IP65 Protection
Valve of Backwash
Butterfly Valve/ Ball Valve
Transport Package
in Polywood
Specification
As required
Trademark
Junyi
Origin
China
HS Code
8421299090
Production Capacity
1000 Pieces/Year

Product Description

Introduction of Automatic Backflushing Filter                                                                    
The Backflushing Filter is a precision equipment, which can remove the suspended solids/particles in the water, reduce the turbidity, reduce the system fouling, bacteria , algae and rust to purify the water quality and assure the normal operation of the system and other equipment. It can realize the automatic filtration/cleaning/slag discharging and no interruption during the backblushing.
Automatic Backflush Filter for Cooling Water


Automatic Backflush Filter for Cooling Water
Technical Parameter                                                                                                               
 
Applicable liquid
 
All kinds of raw material, cooling water, process water and low viscosity liquid (<40 cps), the impurity content should be <300ppm.
Working pressure difference
 
The pressure difference between the outlet of filter and the outlet of backflush >0.15MPA
Filtration precision
 
10----2,000um
Standard designed pressure
 
0.7MPA/1.0MPA
Working temperature
 
0-180ºC
 
Flow range
 
17--10,560M3/H
Cleaning pressure difference
 
 0.05MPA-0.07MPA
 
Control system
 
Siemens controller. Controlled by time and pressure difference.
Inlet/outlet size
 
2''--24''/DN50----DN1000
Valve of backflush
 
Butterfly valve/ ball valve
Actuator of valve
 
Pneumatic or electric, IP65 Protection

Application                                                                                                                               
 
Automatic Backflush Filter for Cooling Water
 

Working Principle                                                                                                                      
 
 
 
 
Automatic Backflush Filter for Cooling Water
 
1.After the liquid has been fed into the automatic backflushing filter from the inlet (3), 50% unfiltered liquid will flow up to the top of the filter (4) from the middle first, then it will flow into the cartridge (5) from the top. The other 50% liquid flows into the cartridge (6) from the bottom directly.
 
2.After the liquid flows into the cartridge from the top and from the bottom at the same time and has been filtered, the clean filtered liquid will flow out from the outlet (7).
 
3.When it reaches to the set pressure difference or the time (9), the filter will start the backflushing automatically. The gear motor will drive the cleaning arm (1) to clean the cartridges one by one, at the same time the filtration will go on continuously.

4.When backflushed, the top of the cartridge will be blocked by the slider (2). The valve of the backflushing will be opened. Because of the pressure difference between the outside of the cartridge and the outlet of the backwash, the filtered clean liquid will rush to the internal surface (8) quickly. The impurities washed down will be discharged from the drain pipe.
Characteristics                                                                                                                         

1.Automatic continuous filtration. The filtration will not stop when backflushing, reducing the stop time and the maintenance cost.

2.The control system can be customized to monitor the pressure of different kinds of the liquid and set the time.

3. Higher precision and larger filtration area.

4. Less pressure drop and higher backflushing efficiency.

5. Cover less space and easy to be installed.

6. The inlet and outlet can be adjusted based on the special requirements of each client.

Service Cases                                                                                                                         
Automatic Backflush Filter for Cooling WaterPackages and Shipment                                                                                                             

 
Automatic Backflush Filter for Cooling Water
 
Automatic Backflush Filter for Cooling WaterContact us                                                                                                                   

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now